Maintenance-Object Repair Procedures
555-233-143
8-196 Issue 1 May 2002
1. Test the ATM-EI circuit pack (test board UUCSS) and investigate
further based on each test’s results. If every test passes, the error
was a transient problem.
Aux Data values: For Setup and Add Party connection request failure type,
the port-network and the angel number of the destination ATM-EI circuit
pack are logged Aux Data values in the form XXYYY, where
■ port-network number = XX
■ angel number = YYY
Aux Data values for WSP Setup (XX = WSP number, YYY = location code).
Since you need to know the slot number also, Table 8-82 converts the Aux
Data to slot numbers.
Table 8-82. Error Type 1024-1151 Aux Data values (XXYYY) converted to
slot number
Slot Carrier
ABC DE
Failure type Failure type Failure type Failure type Failure type
Slot
#
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
Set
up
Add
Party
WSP
Set
up
1 28 528 828 66 566 866 98 598 898 34 534 834 02 502 802
2 29 529 829 67 567 867 99 599 899 35 535 835 03 503 803
3 30 530 830 68 568 868 100 600 900 36 536 836 04 504 804
4 31 531 831 69 569 869 101 601 901 37 537 837 05 505 805
5 56 556 856 70 570 870 102 602 902 38 538 838 06 506 606
6 57 557 857 71 571 871 103 603 903 39 539 839 07 507 607
7 58 558 858 72 572 872 104 604 904 40 540 840 08 508 808
8 59 559 859 73 573 873 105 605 905 41 541 841 09 509 809
9 60 560 860 74 574 874 106 606 906 42 542 842 10 510 810
10 61 561 861 75 575 875 107 607 907 43 543 843 11 511 811
11 62 562 862 76 576 876 108 608 908 44 544 844 12 512 812
12 63 563 863 77 577 877 109 609 909 45 545 845 13 513 813
13 88 588 888 78 578 878 110 610 910 46 546 846 14 514 814
14 89 589 889 79 579 879 111 611 911 47 547 847 15 515 815
15 90 590 890 80 580 880 112 612 912 48 548 848 16 516 816
16 91 591 891 81 581 881 113 613 913 49 549 849 17 517 817
17 92 592 892 82 582 882 114 614 914 50 550 850 18 518 818
Continued on next page