ATM-EI (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-197555-233-143
j. Error type 1153 — The ATM connection audit found some discrepancy in
the firmware’s VC token numbers and live VCs. The problem is rectified in
firmware and no action is needed.
k. Error Type 1281 — The loss of high-level signal indicating operational
problems of equipment located outside of the circuit pack and the fiber
connected to the board. Aux Data values are listed in Table 8-83.
18 93 593 893 83 583 883 115 615 915 51 551 851 19 519 819
19 94 594 894 84 584 884 116 616 916 52 552 852 20 520 820
20 95 595 895 85 585 885 117 617 917 53 553 853 21 521 821
21 NA NA NA 86 586 886 118 618 918 54 554 854 22 522 822
22 NA NA NA 87 587 887 119 619 919 55 555 855 23 523 823
Table 8-83. Error type 1281 Aux Data and repair procedures
Aux
Data
Alarm
Description Repair procedure
15 SYSCLOCK failed The board is not locked to the TDM backplane clock signal. This is
probably due to a Tone-Clock problem.
Check for TDM-BUS or TONE-BD errors in the Error Log.
If no other problems are present, reset the circuit pack (reset board
UUCSS)
Continued on next page