Maintenance-Object Repair Procedures
555-233-143
8-214 Issue 1 May 2002
ATM Board Error Query Test (#1259)
This test is nondestructive. The ATM circuit pack firmware maintains counters for
some of the on- and off-board errors. The maintenance software queries the
board for its health information to do error analysis. These alarms have assigned
priority: if a higher priority alarm occurs, the remaining alarms are not reported to
the software (through the inline errors), avoiding unnecessary up-link, in-line error
message traffic. This is run as a part of a craft demand test sequence periodic
testing, initialization, and error analysis.
ANY FAIL The transmitted data packet was not received correctly by the Packet Interface
circuit pack. The failure can be in the ATM-EI under test, the DS1 CONV circuit
packs, or the intervening Center Stage components.
1. Retry the command at 1-minute intervals up to five times.
2. If the test continues to fail, replace the circuit pack.
PASS The Packet Interface test passed.
Table 8-89. ATM Board Error Query Test (#1259)
Error
Code
Tes t
Result Description / Recommendation
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
XXYY FAIL On-board hardware or off-board signaling errors on the board. XX indicates
the on-board hardware error, and YY indicates the off-board errors on the as
shown in Table 8-90 on page 8-215.
1. Resolve any errors in error logs.
PASS No service effecting errors or alarms were detected on the circuit pack.
Continued on next page
Table 8-88. Packet Interface Test (#598) — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page