Loading...
ATM-NTWK (ATM Network Error)
Issue 1 May 2002
8-237555-233-143
257 to 300
(b)
(b) ATM Impaired Paths
1. Examine the error log (display errors), atm setup-events log (list
measurements atm svc-setup), and atm pnc-latency (list
measurements atm latency) screens to help diagnose the problem
although the switch could be operating normally. In this case, you should
consider raising the Activation threshold and/or increasing the Timeout
value on the ATM-RELATED System Parameters screen. (change
system atm).
You can use the list measurements atm svc-setup command to provide
information about errors associated with connection numbers.
2. After entering the above command, note the time stamps shown in the list
measurements atm setup-events screen. Execute the above command
periodically and note the time stamps. If the time stamps have changed
for a particular From Conn-To Conn pair, this indicates there are still setup
failures/delays for that connection.
3. After verifying that every associated ATM endpoint is operating correctly,
and if errors are still occurring, contact your local service provider.
301 (c) ANY System wide ATM Impaired Paths.
See the suggestions listed above to trouble shoot these errors.
769 (d) ATM CLP (Cell Loss Priority) Bit Errors
1025 (e) ATM Congestion Bit Errors
1281 (f) ATM Cell Underrun Errors
1537 (g) ATM Cell Overrun Errors
1793 (h) ATM Lost Cells
Table 8-99. Error codes and Aux data values ATM-NTWK
Cause Code/
Error Type
Aux
Data Cause Codes Description