Maintenance-Object Repair Procedures
555-233-143
8-238 Issue 1 May 2002
Notes:
a. Aux Data values for Setup and Add Party (XX = Port Network, YYY =
location code).
Aux Data values for WSP Setup (XX = WSP number, YYY = location code).
Table 8-100 is a list of UNI 3.1 location codes:
b. Error Types 257 to 300 — These error type numbers are used to
determine the destination PNC connection number of an ATM Network
connection that is experiencing an impaired path. The connection number
is obtained by subtracting 256 from the number that is shown in the Error
Type field. See the following example:
ERROR TYPE field = 263
Subtract = 256
PNC destination connection # = 7
The AUX DATA field contains the originating and destination EPN number
(XXYY). Where XX = the originating EPN #, and YY = the destination
EPN # for example:
1. AUX DATA = 302
3 = orig
2 = dest
2. Example AUX DATA = 1510
15 = orig
10 = dest
Table 8-100. Location codes from Aux Data values
Setup
(Location
Code)
Add
Party
(Location
Code)
WSP
Setup
(location
Code) Location Code Meaning
0 500 800 User
1 501 801 Private network serving the local user
2 502 802 Public network serving the local user
3 503 803 Transit network
4 504 804 Public network serving the remote user
5 505 805 Private network serving the remote user
7 507 807 International network
10 510 810 Network beyond interworking point
Continued on next page