Maintenance-Object Repair Procedures
555-233-143
8-274 Issue 1 May 2002
ATM-TRK-related commands
Table 8-118 lists some commands that can be useful in troubleshooting ATM
errors and alarms.
Error Log Entries and Test to Clear Values
Table 8-118. ATM CES troubleshooting commands
Command Description
display circuit-packs cabinet Shows the circuit packs in the cabinet, identifying ATM
trunk as well as ATM-EI boards. “ATM Interface” boards
have not been administered as CES or PNC.
display atm ports UUCSSppp Shows the 256 ports on the ATM board with the
corresponding signaling and trunk group.
list configuration atm Lists the ATM boards, identifying equipment location,
board code, type, and vintage.
list configuration trunks Lists boards identifying assigned ports. While the ATM
board is listed, the 256 ports are not.
busyout/release atm signaling-group Busyout or release of an ATM signaling group within a
trunk group.
status atm signaling-group Show current status of an ATM signaling group.
status trunk-group Shows status of the trunk group (ATM signaling groups
are part of trunk groups).
Continued on next page
Table 8-119. ATM-TRK Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
00Any Any test board UUCSS
1(a) None MIN ON
18(b) 0 busyout board UUCSS MIN ON release board UUCSS
23(c) 0 None MIN ON
125(d) None MIN ON
257(e) Any Control Channel Loop
test (#52)
MIN ON test board UUCSS r 2
Continued on next page