4
146.1 Asynchronous motor mode
Bit string to select the control mode of an asynchronous motor
146.13 Flux set value
Set value of the flux in percent
146.14 Actual flux
Actual value of the flux in percent
146.16 Slip preset value
(this is relevant at asynchronous motors with encoder, only)
Slip preset value between electrical and mechanical frequency [Inc/Tab].
It is calculated from lsq set value, flux set value (Z146.13) and the "slip frequency tem-
perature actual value" (Z19.30). Refer to ZTemperature adaption slip frequencyon
page 527.
Bit no. Meaning
7 ... 0 Reserved
8 Build-up of the flux before the transition in state 4 (Z108.6):
1: on
0: off
9 Reserved
10 Command start of the Lh-identification
15 ... 11 Reserved