EasyManua.ls Logo

Baumuller b maXX BM3000 - Page 269

Baumuller b maXX BM3000
822 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
269
of 820
4
124.33 DS402 touch probe 2 pos. value
DS402 touch probe object 0x60BC
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)
124.34 DS402 touch probe 2 neg. value
DS402 touch probe object 0x60BD
The source is selected in Z124.30.
The following scalings are possible:
m according to Z124.30 bits 9 ... 4 (Z124.30 bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2 to Z179.9 (Z124.30
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17 (Z124.30
bit 2 ... 1 = 10)

Table of Contents