Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
269
of 820
4
124.33 DS402 touch probe 2 pos. value
DS402 touch probe object 0x60BC
The source is selected in Z124.30–.
The following scalings are possible:
m according to Z124.30– bits 9 ... 4 (Z124.30– bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2– to Z179.9– (Z124.30–
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17– (Z124.30–
bit 2 ... 1 = 10)
124.34 DS402 touch probe 2 neg. value
DS402 touch probe object 0x60BD
The source is selected in Z124.30–.
The following scalings are possible:
m according to Z124.30– bits 9 ... 4 (Z124.30– bits 2 ... 1 = 00) or
m with the Factor Group weightings from Z179.2– to Z179.9– (Z124.30–
bit 2 ... 1 = 01) or
m position system of the modulo actual position value Z121.17– (Z124.30–
bit 2 ... 1 = 10)