Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
343
of 820
4
n Speed Control (Operating mode -3)
Sense of the bits inverted with respect to the Speed Setting 1 mode (Operating
mode 2)
1: Inhibit ramp function generator (set output to 0)
0: Enable ramp function generator (enable output)
n Target Position Setting (Operating mode 1)
1: Start positioning if control of positioning is via "New Set Value"
n Reference run mode (Operating mode 6)
1: Start reference run
n Coupled operation (operation mode -12)
0->1 Activate switchover to a reloaded curve
m Bit 5 - Ramp FG Stop / Change set immediately:
n Target Position Setting (Operating mode 1)
Change set immediately
This bit is dependent on the setting in Parameter 118.2, Positioning
Mode bit 11 active low or active high.
118.2 Positioning mode Bit 11 = 0:
0: Single set value: Procedure of individual positioning records
1: Set-of-set values: Procedure with a speed profile.
118.2 Positioning mode Bit 11 = 1:
0: Set-of-set values
1: Single set value
n Speed Setting 1 (Operating mode 2)
1: Enable ramp function generator ramp-up
0: Inhibit ramp function generator ramp-up.Output is frozen
n Speed Control (Operating mode -3)
Sense of the bits inverted with respect to the Speed Setting 1 mode (Operating
mode 2)
1: Inhibit ramp function generator ramp-up. Output is frozen
0: Enable ramp function generator ramp up
n Coupled operation (operation mode -12)
0->1 Perform sequence change
m Bit 6 - Ramp FG zero / absolute / relative target specification
n Target Position Setting (Operating mode 1)
0: Absolute target specification
1: Relative target specification
n Speed Setting 1 (Operating mode 2)
1: Enable ramp FG input
0: Set ramp FG input to zero (braking with ramp)
n Speed Control (Operating mode -3)
Sense of the bits inverted with respect to the Speed Setting 1 mode (Operating
mode 2)
1: Set ramp function generator input to zero (braking with ramp)
0: Enable ramp function generator input
n Coupled operation (operation mode -12)
0->1 Activate additional movement