Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
345
of 820
4
m Bit 13:
For all operating modes: inhibit operating mode changeover
To avoid inconsistencies between the set operating mode and the mode-dependent bits,
the mode changeover can be inhibited selectively. When the bit is set, the set operating
mode remains active. Any intended change to the operating mode will only be adopted
when the bit is cleared. A new operating mode can thus be activated synchronously with
the control word. The instantaneous state of the mode changeover is indicated in
Z108.5 Status Word 2.
0: Enable mode changeover
1: Inhibit mode changeover