Error messages and troubleshooting
Parameter manual b maXX BM3000
Document no.: 5.12001.07
765
of 820
5
1716 Indicated data field size cannot be
changed
Pulse block
1717 Indicated word address is outside of
the data field
Pulse block
1718 No data field or addressed data field
does not exist
Pulse block
1728 Amount monitoring for analog signals
(process data)
Amount monitoring for analog signals (process data) Pulse block
1729 Transmission current critical (contami-
nation, transmission break)
Transmission current critical (contamination, transmission break) Pulse block
1730 Encoder temperature critical Encoder temperature critical Pulse block
1731 Speed too high, no position establish-
ment possible
Speed too high, no position establishment possible Pulse block
1732 Speed too high, position can't be calcu-
lated
At rotatory encoders:
m position can't be calculated
At linear encoders:
m sensor is not adjusted or is not in adjustment mode
Pulse block
1733 Position error At rotatory encoders:
m Position error Multiturn
At linear encoders:
m distance magnetic tape/sensor too high
Pulse block
1734 Position error At rotatory encoders:
m Position error Multiturn
At linear encoders:
m Positional error
Pulse block
1735 Position error Multiturn Position error Multiturn Pulse block
1752 Error while initializing the encoder
(multiple errors)
Error while initializing the encoder (multiple errors) Pulse block
1753 Position generally not dependable Encoder position not dependable. Quotient of resolution to line num-
ber faulty
Pulse block
1754 Unknown error from encoder Unknown error code from the encoder Pulse block
1800 no or invalid data in the encoder motor
type plate
The error occurs when no motor data can be read from the encoder
after rebooting.
Pulse block
1801 Invalid section found in the encoder
OEM memory
Invalid section found while reading the encoder memory. Reference
to wrong data in the OEM memory of the encoder.
Pulse block
1802 too many sections of the type "variable
operating data"
Pulse block
1803 Index for addressing the section for
variable operating data too large
Pulse block
1805 Checksum error in Section Pulse block
1806 Version of imported data structure
unknown
Pulse block
1808 Wrong quantity (0 or 128) Pulse block
1809 Wrong data field (only 0 or 1 permitted) Pulse block
1810 Data field start address too large (=
128)
Pulse block
1813 No memory available in the encoder Pulse block
1814 Faulty data in the section Data in the section is not plausible (WordCount is 0 or too large) Pulse block
Error
num-
ber
Brief error text Error description Default set-
ting for
Error
Response