EasyManuals Logo
Home>Cisco>Network Router>ASR 1002

Cisco ASR 1002 Hardware Installation Guide

Cisco ASR 1002
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #480 background imageLoading...
Page #480 background image
DescriptionLED Color and State
A power supply warning event has occurred, but the
power supply can continue to operate. The warning
event can be temperature, voltage, current, or fan
operating outside the normal operating range.
Blinking amber, at the rate of one blink per second
Power supply is shut down.Off
This section contains the following topics:
The covers are an integral part of the safety design of the product. Do not operate the unit without the
covers installed. Statement 1077
Warning
When you install the unit, the ground connection must always be made first and disconnected last. Statement
1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Installing AC Input Power to Cisco ASR 1001 Router
The Cisco ASR 1001 Router has two AC power supplies in the rear of the chassis. The input receptacle is an
IEC60320 C14 type of filtered AC inlet. The current rating on the connector is 10 A.
Do not install the power supplies with the chassis cover off.Warning
Cisco ASR 1000 Series Router Hardware Installation Guide
446
Cisco ASR 1001 Router Overview and Installation
Installing AC Input Power to Cisco ASR 1001 Router

Table of Contents

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g