Removing DC Input Power from the Cisco ASR 1001 Router
This section describes how to remove a DC power supply from the Cisco ASR 1001 Router. Follow these
steps:
SUMMARY STEPS
1.
Turn off the circuit breaker.
2.
Pull the terminal block plug connector out of the terminal block head in the power supply.
3.
Unscrew the two power supply fasteners on the unit.
4.
Grasping the power supply handle with one hand, pull the power supply out of the chassis while supporting
it with the other hand.
DETAILED STEPS
Step 1
Turn off the circuit breaker.
Step 2
Pull the terminal block plug connector out of the terminal block head in the power supply.
Step 3
Unscrew the two power supply fasteners on the unit.
Step 4
Grasping the power supply handle with one hand, pull the power supply out of the chassis while supporting it with the
other hand.
What to Do Next
This completes the procedure for removing the DC power supply from the Cisco ASR 1001 Router.
Cisco ASR 1000 Series Router Hardware Installation Guide
459
Cisco ASR 1001 Router Overview and Installation
Removing DC Input Power from the Cisco ASR 1001 Router

Table of Contents

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g