Cisco ASR1000-RP2Cisco ASR1000-RP1
Up to 4 DIMMs with up to two DIMMs per
channel
DDR-533
Allowable memory options of 4 GB, 8 GB, or
16 GB
DDR-667
You might need to upgrade the DIMM for the following reasons:
You have upgraded to a new Cisco IOS feature set or release that requires more memory.
You are using very large routing tables or many protocols.
This section contains the following topics:
Removing and Replacing the DIMM Memory Modules on the Cisco ASR 1006
Router and the Cisco ASR 1013 Router
The Cisco ASR 1006 Router and the Cisco ASR 1013 Router have redundant RPs. The following is an
overview of the steps to remove and replace the DIMM memory modules on these routers:
Cisco ASR 1000 Series Router Hardware Installation Guide
495
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the DIMM Memory Modules on the Cisco ASR 1006 Router and the Cisco ASR 1013 Router

Table of Contents

Other manuals for Cisco ASR 1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco ASR 1002 and is the answer not in the manual?

Cisco ASR 1002 Specifications

General IconGeneral
Ethernet LANYes
Cabling technology10/100/1000Base-T(X)
Networking standardsIEEE 802.3
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
DHCP client-
Supported network protocolsBGP, GRE, OSPF, DVMRP, EIGRP, IS-IS, IGMPv3, PIM-SM, PIM-SSM
Ethernet LAN (RJ-45) ports4
Security algorithmsSSH
VPN tunnels quantity8000
SafetyUL60950-1 CSA, C22.2 No. 60950-1-03, EN 60950-1, IEC 60950-1, AS/NZS 60950.1
CertificationFCC 47CFR15 Class A AS/NZS CISPR 22 CISPR 22 Class A EN55022 Class A ICES-003 Class A VCCI Class A CNS-13438 Class A EN61000-3-2 EN61000-3-3
Internal memory4096 MB
AC input voltage85 - 264 V
Power source typeAC
AC input frequency50 - 60 Hz
Power consumption (typical)560 W
Operating altitude0 - 3048 m
Storage temperature (T-T)0 - 50 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)5 - 90 %
Product colorGray
Rack capacity2U
Weight and Dimensions IconWeight and Dimensions
Depth461 mm
Width437.4 mm
Height89 mm
Weight- g