172
To disable SMPTE operation
1 Press
SETUP.
2 Tap
SYSTEM OPTIONS.
3 Tap
I/O.
4 Tap
SMPTE.
5 Tap
ENABLE.
ENABLE appears on a light field.
To set the number of frames
In the SMPTE menu (SETUP > SYSTEM OPTIONS > I/O), use wheel three to set the number
of frames. Up to 50 frames per second is the maximum allowed.
Setting SMPTE triggers for cues
You can manually set a time for SMPTE to trigger cues or use the Teach SMPTE feature.
To set SMPTE time
1 Press
EDIT.
2 Select the Qlist and cue.
3 Press
TIME.
4 Tap
SMPTE.
5 Use the wheels to set the time.
Note: To set hours, press and hold
SHIFT and turn wheel 1.
To use Teach SMPTE with the internal clock
1 Load a QList to the crossfader.
2 Press
SETUP.
3 Tap
SYSTEM OPTIONS.
4 Tap
I/O.
5 Tap
SMPTE.
6 Tap
TEACH SMPTE to enable.
The SMPTE clock starts running. It can be seen in the command line.
7 Each press on
GO, to fade from cue to cue, captures the SMPTE clock time.
8 When complete, disable
TEACH SMPTE.

Table of Contents