28
Compulite
Chapter 2
To set the dimmer curve
Example: Set preheat for dimmer 10.
1 Press
SETUP.
2 Tap
PATCH BY FIXTURE.
The
DMX Channel Properties screen is displayed on the touch screen. The patch is
displayed on the external monitor.
3 Tap
DIMMERS.
Dimmer information is displayed on the touch screen and the external monitor.
4 Select the dimmers.
5 Tap
CURVE.
6 Tap
PREHEAT.
7 Tap
OK.
GM on or GM off
By default, all dimmers are under general master control. You can remove dimmers from general
master control. This is used for fixtures that should never go to black.
To remove dimmers from general master control
Example: Remove channel 10 from general master control.
1 Press
SETUP.
2 Tap
PATCH BY FIXTURE.
The
DMX Channel Properties screen is displayed on the touch screen. The patch is
displayed on the external monitor.
3 Tap
DIMMERS.
Dimmer information (curve, proportional patch, and GM status) is displayed on the touch
screen and the external monitor.
4 Select the dimmers.
5 Tap
GM OFF.
6 Tap
OK.
To return dimmers to general master control
Example: Remove channel 10 from general master control.
1 Press
SETUP.
2 Tap
PATCH BY FIXTURE.
The
DMX Channel Properties screen is displayed on the touch screen. The patch is
displayed on the external monitor.
3 Tap
DIMMERS.
Dimmer information (curve, proportional patch, and GM status) is displayed on the touch
screen and the external monitor.

Table of Contents