49
DLITE
Selecting Fixtures and Setting Levels
Releasing parameter levels from the editor
You can release fixtures, single or multiple parameters, or all parameter levels in the selected bank
from the editor. Released parameters and fixtures are not included when storing a scene, chase step,
or cue. Released parameters fade to home levels or maintain their current level, according to the
MAINTAIN LAST LEVEL setting ( see “Maint. Last Level” page 165).
To release fixtures
Select fixtures and tap RELEASE or press REL(ease).
To release one parameter
1 Select fixtures.
2 Press
F, B, or C to choose the parameter bank.
3 Press a parameter wheel to select the parameter.
4 Tap
RELEASE or press REL(ease).
To release levels per parameter bank
1 Press
F, or C, or B to select the parameter bank.
Skip this step if one of the parameters in the bank is active (appears in red in the live fixture
display).
2 Press
SHIFT + REL(ease)
Or
Press
SHIFT and tap RELEASE.
The levels for all the parameters in the selected bank are released from the editor.
Resetting and recalling the editor
Resetting the editor clears all selections and levels in the editor.
To reset the editor
Press RESET. All levels held in the editor are released in a 2 second fade.
Or
Press RESET RESET quickly. All levels held in the editor bump out.
To recall the last editor state
Press SHIFT + RESET. All fixtures and parameter levels, which were active in the editor prior
to pressing
RESET, are recalled to the editor.
About groups