48
Compulite
Chapter 3
To home parameters grouped in the same wheel bank
Example: Home levels for all parameters in the beam bank.
1 Select the fixtures.
2 Press
BEAM.
3 Press and hold
SHIFT and tap HOME FCB.
All parameters in the selected bank fade to their home levels.
To home selected parameters
1 Select the spots.
2 Select the parameters.
3 Press
HOME.
To create a scene for unusual home level requirements
Parameters in some fixtures may require home levels that are different than those defined in
the device definition. A few examples of this: an unusual hanging position that requires special
home levels for pan and/or tilt, a gobo or color wheel that is not identical to the wheels in the
same devices. In these instances, you create a scene that contains levels that are referenced
when the parameters return to their home values.
1 Select the spots that have special home level requirements.
2 Select the parameter that has special home value requirements and set its unique home
level.
3 Repeat steps 1 and 2 for all fixtures and parameters as necessary.
4 Save as a scene:
STORE, SCENE #, ENTER.
Tip: Label this scene as “special home levels” or any other name that helps identify it as the
special home value scene.
5 Press
SETUP.
6 Tap
SYSTEM OPTIONS.
7 Tap
DEFAULTS.
8 Tap
SPOT HOME VALUES.
The touch screen grid is now is scene mode.
9 Select the special home value scene.
10 Tap
OK.
Note: To cancel the special home levels, simply delete the scene.