Option Name Description
[150] Homing Start The drive moves to the home position.
[151] Home Ref. Switch Indicate the status of the home referenced
switch. On means that the home position
is reached, off means that the home
position is not reached.
[155] HW Limit Positive Inv The positive hardware position limit is
exceeded. This option is active on the
falling edge.
[156] HW Limit Negative Inv The negative hardware position limit is
exceeded. This option is active on the
falling edge.
[157] Pos. Quick Stop Inv Stop the drive during positioning with the
ramp time that is set in parameter 32-81
Motion Ctrl Quick Stop Ramp. This option
is only effective when parameter 37-00
Application Mode is set to [2] Position
Control.
[158] Pos. Jog Forward
[159] Pos. Jog Reverse
[160] Positioning Start The drive moves to the target position.
This option is only effective when
parameter 37-00 Application Mode is set
to [2] Position Control.
[162] Pos. Idx Bit0 Position index bit 0. This option is
only effective when parameter 37-00
Application Mode is set to [2] Position
Control.
[163] Pos. Idx Bit1 Position index bit 1. This option is
only effective when parameter 37-00
Application Mode is set to [2] Position
Control.
[164] Pos. Idx Bit2 Position index bit 2. This option is
only effective when parameter 37-00
Application Mode is set to [2] Position
Control.
[231] Power Limit Mot.
[232] Power Limit Gen.
[233] Power Limit Both
116 | Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507
Programming Guide | VLAutomationDrive FC 360