Programming Guide | VLT® AutomationDrive FC 360
Table 19: Device Identification 1st Sub-index Assignment (continued)
Index Content Value
5 No. of axes Variable
6 Vendor specific: PB/PN Version xxyy
7 Vendor specific: Database Version xxyy
8 Vendor specific: AOC Version xxyy
9 Vendor specific: MOC Version xxyy
9-65 Profile Number
Default value: 0 Parameter type: Range (0–0)
Setup: All setups Conversion index: 0
Data type: OctStr Change during operation: True
This parameter contains the profile identification. Byte 1 contains the profile number and byte 2 the version number of the profile.
9-67 Control Word 1
Default value: 0 Parameter type: Range (0–65535)
Setup: All setups Conversion index: 0
Data type: V2 Change during operation: True
This parameter accepts the control word from a master class 2 in the same format as PCD 1.
9-68 Status Word 1
Default value: 0 Parameter type: Range (0–65535)
Setup: All setups Conversion index: 0
Data type: V2 Change during operation: True
This parameter delivers the status word for a master class 2 in the same format as PCD 2.
9-70 Edit Set-up
Default value: [9] Active Set-up Parameter type: Option
Setup: 1 setup Conversion index: –
Data type: Uint8 Change during operation: True
Select the setup in which programming (change of data) is performed during operation. It is possible to program the 2 setups
independently of the setup selected as active setup. Parameter access from each master is directed to the setup selected by the
individual master (cyclic, acyclic MCL1, 1st acyclic MCL2, 2nd acyclic MCL2, 3rd acyclic MCL2).
Danfoss A/S © 2024.01 AU275649936274en-001401 / 130R0507 | 199