Field Service Ver. 1.0 Aug. 2005 9. Utility/Counter Mode
119
bizhub 200/250/350Adjustment / Setting
9.3.3 User’s Choice 3/6
A. Low Power Mode
B. Sleep Mode
C. LCD Back-Light OFF
D. Auto Reset
Functions
To set the time until Low Power starts operating after the last key operation has been
completed.
Low Power: To turn LED and LCD OFF, and lower the power consumption.
Use To change the time until Low Power starts.
Setting/
Procedure
Use the 10-Key Pad for setting.
The default setting is “15 min.
“15 min.” (10 to 240)
Functions
To set the time until Sleep Mode starts operating after the last key operation has been
completed.
Turn all lines OFF except 3.3 V line for Control.
“OFF” will only be displayed when “Disable Sleep Mode” in Admin. Management is set.
Use To change the time until the Sleep Mode starts.
Setting/
Procedure
Use the 10-Key Pad for setting.
The default setting is “15 min.
“15 min” (1 to 240) OFF
Functions
To set the time until LCD Back-Light OFF starts operating after the last key operation
has been completed.
Use
To change the time until LCD Back-Light OFF starts operating after the last key opera-
tion has been completed.
Setting/
Procedure
Use the 10-Key Pad for setting.
The default setting is “1 min.
“1 min” (1 to 240)
Functions
To set the time until Auto Reset starts operating after the last key operation has been
completed.
Auto Reset: Resets the panel to the default settings.
Use
To change the time until Auto Reset starts operating after the last key operation has
been completed.
Setting/
Procedure
The default setting is “1 min.
30 seconds “1 min” 2 min
3 min 5 min OFF

Table of Contents