Field Service Ver. 1.0 Aug. 2005 4. Periodical check
37
bizhub 200/250/350Maintenance
4.6 Replacing the unit
4.6.1 Replacement of the Fusing Unit
CAUTION
• From the safety viewpoint, the Fusing Unit is replaced as a unit. No parts intended
for other models should be used for the Fusing Unit of this machine. Note, how-
ever, that the thermistor and several other parts mentioned in this machine may be
replaced as an individual part with a new one.
1. Open the Right Door.
2. Remove the Rear Right Cover.
☞ 50
3. Remove the screw [1] and the Front
Right Cover [2].
4. Unplug two connectors [3] of the
Switch Back Unit.
5. Loosen the screw [4] in front.
6. Remove the screw [5] in front.
7. Loosen the screw [6] in the back.
8. Remove the screw [7] in the back.
9. Remove the Switch Back Unit [8].
4040F2C560DA
[2]
[1]
4040F2C563DA
[3]
4040F2C564DA
[4]
[5]
[6]
[7]
4040F2C565DA