EasyManua.ls Logo

Develop ineo 350 - Replacement of the Fusing Unit; Replacing the Unit

Develop ineo 350
770 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Field Service Ver. 1.0 Aug. 2005 4. Periodical check
37
bizhub 200/250/350Maintenance
4.6 Replacing the unit
4.6.1 Replacement of the Fusing Unit
CAUTION
From the safety viewpoint, the Fusing Unit is replaced as a unit. No parts intended
for other models should be used for the Fusing Unit of this machine. Note, how-
ever, that the thermistor and several other parts mentioned in this machine may be
replaced as an individual part with a new one.
1. Open the Right Door.
2. Remove the Rear Right Cover.
50
3. Remove the screw [1] and the Front
Right Cover [2].
4. Unplug two connectors [3] of the
Switch Back Unit.
5. Loosen the screw [4] in front.
6. Remove the screw [5] in front.
7. Loosen the screw [6] in the back.
8. Remove the screw [7] in the back.
9. Remove the Switch Back Unit [8].
4040F2C560DA
[2]
[1]
4040F2C563DA
[3]
4040F2C564DA
[4]
[5]
[6]
[7]
4040F2C565DA
[8]

Table of Contents