Field Service Ver. 1.0 Aug. 2005 2. Periodical check
3
PC-102/PC-202Maintenance
Maintenance
2. Periodical check
2.1 Maintenance procedure (Periodical check parts)
2.1.1 Replacing the Separation Roller Assy
1. Remove the Right Door.
☞ 10
2. Remove two screws [1] and remove
the Jam Access Cover [2].
3. Remove two screws [3] and remove
the Paper Separation Roller Mount-
ing Bracket Assy [4].
4. Remove two C-rings [5] and the
shaft [6], and remove the Paper Sep-
aration Roller Fixing Bracket Assy
[7].
NOTE
• Be careful not to lose spring at this
time.
5. Remove the C-ring [8], the Guide [9],
and remove the Separation Roller
Assy [10].
6. Repeat steps 1 to 5 similarly for the
4th Drawer.
4348fs2611c0
[1]
[2]
[1]
4348fs2612c0
[3]
[4]
[3]
[5]
[5]
[6]
[7]
4061F2C500DA
[8]
[9]
[10]
4061F2C501DA