Field Service Ver. 1.0 Aug. 2005 6. Tech. Rep. Mode
21
DF-605Adjustment / Setting
6.5 Setting in the Operation Check
6.5.1 Paper Passage
6.5.2 ADF Sensor Adjust
6.5.3 Backup Data Initialization
Functions To check for paper passage through the ADF in each of the ADF modes.
Use Used for checking the document path for any abnormal condition when a document
misfeed occurs.
Setting/
Procedure
<Procedure>
1. Set the mode to the Tech. Rep. Mode.
2. Touch the [Operation Check].
3. Touch the [ADF].
4. Touch the [Paper Passage].
5. Select the Paper Passage Mode to be tested from [1-Sided No Detect] and
[Double-Sided].
6. Set the Original in the Take-up Tray.
7. The Start key color changes from orange to green.
8. Press the Start key. The operation starts.
NOTE
After starting the operation by pressing the Start key, if the Start key is pressed
during the operation, the operation will be suspended. Then, if the Start key is
pressed again during the suspension, the operation will be resumed.
If the Stop key is pressed during the test operation, the test will be forced to end.
If there is no Original set in the Take-up Tray, the Start key will not work.
All Originals set in the Take-up Tray are passed through. Upon the completion of
all Originals passed through, the Paper Through Test ends.
Functions To make an automatic adjustment of the sensor.
Use When a document misfeed occurs.
When the sensor is replaced.
Setting/
Procedure
<Procedure>
1. Set the mode to the Tech. Rep. Mode.
2. Touch the [Operation Check].
3. Touch the [ADF].
4. Touch the [ADF Sensor Adjust].
5. Press the Start key to let the ADF start making an automatic adjustment of the sensor.
Functions To initialize the values set through ADF Sensor Adjust and Org. Width Detect Adjust.
Use When the Main Control Board is replaced.
When the Variable Resistor is replaced.
Setting/
Procedure
<Procedure>
1. Set the mode to the Tech. Rep. Mode.
2. Touch the [Operation Check].
3. Touch the [ADF].
4. Touch the [Backup Data Initialization].
5. [Touch [Yes] and [Enter] to start the initialization sequence.