11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
84
FK-503
Adjustment / Setting
MODE Factory setting bit
057
Bit: 7654 3210
0001 0100
HEX:19
Bit Feature
Logic
Description
01
7 Select the time from when
line is blocked to when
ANSam TX starts.
Bit 7-0: Specify the time from
when line is blocked to
when ANSam TX starts.
6 00000000 Not available
5 00000001 100 msec
4|
3
00011001 2500 msec
2|
1 11111111 25500 msec
0
MODE Factory setting bit
077
Bit: 7654 3210
0110 0000
HEX:60
Bit Feature
Logic
Description
01
4 # of times of hooking
monitoring during ringing
Bit 4-3:
00 3
3015
10 8
11 12