11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
138
FK-503
Adjustment / Setting
NOTE
The features with (*) are settable by users. <*>: Soft switch setting
MODE Factory setting bit
429
Bit: 7654 3210
0000 0000
HEX:00 (For U.S.)
HEX:04 (For Europe)
Bit Feature
Logic
Description
01
7 Set drum dry when
engine power is on
Not exe-
cute
Execute Set whether to switch automatically to
Photo mode when selecting OHP trans-
parencies.
6 Correspond to OHP offset
Not
switch
quality
mode
Switch
quality
mode
5 Automatically reset values
on the basic screen at
completion of copying
using the document
feeder. <*>
No Ye s
4 Set curl correction Bit 4-3:
00 Not control
3 01 All-environ-
ment control
10 Control for
HH, LL envi-
ronments
11 Not available
2 Correspond to fluores-
cent lamp flickering
Control Not con-
trol
1 Setting of time that fan
spin at full speed.
Bit 1-0:
00 20 sec
0 01 55 sec
10 10 min
11 Not available