7. Test Mode Field Service Ver. 1.0 Aug. 2005
28
FS-508/PU-501/OT-601
Adjustment / Setting
8: Creasing Unit movement mode (appears only when the Saddle Kit SD-502 is
installed)
For details, see SD-502 Service Manual.
9: Saddle Unit exit open/close mode (appears only when the Saddle Kit SD-502 is
installed)
For details, see SD-502 Service Manual.
10: Transport drive mode
Transport drive is performed for the predetermined time. (Performs the same transport
drive as the pre-drive with the high speed of the connected copier.)
Drives the Entrance Motor (M3-FN).
Drives the Transport Motor (M2-FN).
Drives the Exit Motor (M1-FN).
The operation is finished.
If the Mail Bin Kit MT-501 is installed, the Mailbins are also driven.
If the Saddle Kit SD-502 is also installed, the Saddle Transport Motor (M8-SK) is also
driven.
11: Shutter drive mode
Opens and closes the Shutter.
The Exit opens.
The Shutter closes.
Stops after the predetermined time.
The Shutter opens.
The Exit closes.
The operation is finished.
12: Mailbin Solenoid movement mode (appears only when the Mail Bin Kit MT-501 is
installed)
For details, see MT-501 Service Manual.
13: Storage Paddle operation mode
Performs the single rotate operation for the Storage Paddle.
The operation is finished.
14: Exit Paddle movement mode
Performs the single rotate operation for the Storage Paddle.
The operation is finished.