CHAPTER 2 WIRING
2-54
Description of I/O Signals
2
Edit permission: Sequence input signal (Reference value 55)
Editing operation for parameters and so on is limited with an external sequence input signal.
Function
The edit permission assigned to a CONT input signal controls editing operation and test operation
made at the keypad or PC Loader.
The following operation can be executed only while the edit permission remains turned on.
Parameter edit mode
Positioning data edit mode
Test operation mode
When the edit permission assigned to a CONT input signal is turned off, only the monitor mode
can be executed. This function can be used to avoid inadvertent operation of the keypad or PC
Loader, thereby avoiding movement of the servomotor, drop of the machine, etc.