CHAPTER 10 PERIPHERAL EQUIPMENT
10-8 Cable Size
10
3-phase 200 V
Rated rotation
speed
[r/min]
Capacity
(Po)
[kW]
Input voltage
(Vac)
[V]
Internal power
consumption
(Pi)
[W]
Input current
(Iin)
[A]
Input current for
selection of peripheral
equipment
(Iin×1.5) [A]
0.05 0.4 0.6
0.1 0.7 1.1
0.2 1.4 2.1
0.4 2.7 4.0
0.75 5.0 7.4
1.0 6.6 9.8
1.5 9.8 14.7
2.0 13.0 19.5
3.0 19.5 29.3
4.0 26.0 39.0
3000
5.0 32.5 48.7
0.5 3.3 5.0
0.75 5.0 7.4
1.0 6.6 9.8
1.5 9.8 14.7
2.0 13.0 19.5
3.0
19.5 29.3
4.0
26.0 39.0
5.5
35.7 53.5
2000
7.0
45.4 68.1
0.5 3.3 5.0
0.85 5.6 8.4
1500
1.3
170* 15
8.5 12.8
* -15% of 200 V
10.2.4 Conditions for Selecting Peripheral Equipment of Servo
Amplifier
To select peripheral equipment for a single servo amplifier
Obtain "1.5 times" the input current (Iin) obtained above.
To select peripheral equipment for two or more servo amplifiers
Multiply "1.5 times" the sum of the input currents (Iin) of all servo amplifiers.
[Example] In case of two 200 W units and three 400 W units (In case of single-phase 200 V)
I = {(2.4 × 2) + (4.7 × 3)} × 1.5 = 28.35 A
Select peripheral equipment having 28.35 A or a larger rated current.