EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - PA1_41 to 47 Manual Feed Speed;Speed Limit for Torque Control

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4 PARAMETER
Basic Parameters 4-25
4
Timing chart
PA1_41 to 47 Manual feed speed/speed limit for torque control
No. Name Setting range
Default
value
Change
41
Manual feed speed 1 for
position and speed control/
speed limit 1 for torque control
100.00 Always
42
Manual feed speed 2 for
position and speed control/
speed limit 2 for torque control
500.00 Always
43
Manual feed speed 3 for
position and speed control/
speed limit 3 for torque control
1000.00 Always
44
Manual feed speed 4 for
position and speed control/
speed limit 4 for torque control
100.00 Always
45
Manual feed speed 5 for
position and speed control/
speed limit 5 for torque control
100.00 Always
46
Manual feed speed 6 for
position and speed control/
speed limit 6 for torque control
100.00 Always
47
Manual feed speed 7 for
position and speed control/
speed limit 7 for torque control
0.01 to
max. rotation speed [r/min]
100.00 Always
Enter the speed of manual feed for speed control and position control.
For torque control, if PA2_56 (speed limit selection at torque control) is "0," the reference value of
PA1_26 (maximum rotation speed) becomes the speed limit.
If PA2_56 (speed limit selection at torque control) is "1," the speed limit is enabled as shown on the
next page.
Combine input signals (CONT signal: multi-step speed selection 1 [X1] to 3 [X3]) to select.
Time
Rotation
speed
Forward command
FWD
OFF
ON
OFF
PA1_37: Acceleration time 1
PA1_40: Deceleration time 2
ACC0
OFF
ON
2000 r/min

Table of Contents

Related product manuals