CHAPTER 10 PERIPHERAL EQUIPMENT
Optional Equipment 10-37
10
Monitor (CN4)
A measuring instrument or similar is connected to the connector 4 (CN4) of the servo amplifier.
The signal of this connector is analog output voltage for measuring instrument and is not necessary
for servo amplifier operation.
This connector is not prepared as option.
1
MON1 3 M5(0 V)
2 MON2 4 M5(0 V)
External regenerative resistor (1)
Model: WSR-401
Applicable range: servo amplifier model: RYH201F5-VV2, RYH401F5-VV2
182.5±1.5
172±1
1000
+100
0
20±0.3
取付部分の厚みは12m
42.5
150±1
Connect the regenerative resistor to the servo amplifier with a 10 m or shorter cable.
The external regenerative resistor becomes hot. Keep flammable matters away from the
external regenerative resistor.
For connection of the external regenerative resistor, refer to "10.8 External Regenerative
Resistor."
Item
Model
Resistor
Thermistor
Resistance
Allowable power
Operating temperature
Dielectric strength
Contact capacity
Specifications
WSR-401
68 Ω
17 W (cont.)
Open at 135 ±10°C
For 1 minutes at 1.5 kV AC
30 VDC 3 A
* Thickness of the installed section: 1.2 mm
Model and manufacturer
Crimp socket DF11-4DS-2C
Crimp terminal DF11-2428SC
Hirose Electric Co., Ltd.