CHAPTER 14 PC LOADER
Detail Description of Function 14-25
14
14.6.4 Parameter Editing
Servo amplifier parameters are edited.
The following functions can be used on this screen.
(1) Reload
Parameters are read out from the connected servo amplifier.
(2) Send changes
Changed parameters are sent to the connected servo amplifier.
(3) Send all
All parameters are sent to the connected servo amplifier.
(4) Comparison
The edited parameters are compared with those of the connected servo amplifier or those having
been saved in a file.
(5) Initialization
Currently edited parameters or those of the connected servo amplifier* are reset to default values.
* This function can be executed only while the servo is turned off. After initializing, turn the servo
amplifier off then on again.
(6) File information
Data about currently edited parameter file. The type, date, comment and so on of the servo
amplifier and servomotor connected at the time of loading can be monitored.
Send parameters ((2) and (3)) while the servomotor is stopped to make sure of safety.
Otherwise movement characteristics may change, possibly giving damage to equipment.
(1) (2) (3) (4) (5) (6)