CHAPTER 6 KEYPAD
Positioning Data Edit Mode 6-41
6
(3) Rotation speed
Set the travel speed to the motor target position. Use the
motor shaft rotation speed for the setting value. The setting
value range is from 0.01 to 6000.00 r/min in increments of
0.01.
Note that the setting speed is not the machine travel
speed.
(4) Stand still timer
Set the stop time after the motor has reached the target
position. The setting value range is from 0.00 to 655.35 s in
increments of 0.01.
After the stop time has elapsed, the sequence output signal
(in-position signal [INP]) turns on.
The decimal point position can be changed in the
parameter PA2-42 (timer data decimal point position).
Pd_3
SET
(1 sec. or over)
60
----
00