EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - Edit Permission Response: Sequence Output Signal (Reference Value 29); Servo Control Ready [S-RDY]: Sequence Output Signal (Reference Value 28)

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2 WIRING
Description of I/O Signals 2-75
2
Servo control ready [S-RDY]: Sequence output signal (Reference value 28)
Use the signal to check that the servo amplifier and servomotor operate correctly.
Function
The servo control ready signal remains turned on while the conditions listed in the table below are
satisfied.
Signal
division
Signal name
Function
No.
Signal status
Forced stop [EMG] 10 ON
CONT input
Free-run 54 OFF
OUT output
Alarm detection (Normally
open contact)
16 OFF
The internal CPU operates correctly. -
The L1, L2 and L3 terminals are turned on. -
Parameter setting
To assign servo control ready to a sequence output terminal, specify the corresponding value
("28") to the output terminal function setting parameter.
Edit permission response: Sequence output signal (Reference value 29)
The signal is output if the "edit permission" input signal for enabling editing operation for parameters,
etc. is turned on.
Function
After the edit permission assigned to a CONT input signal is on, under some conditions, the "edit
permission response command" is turned on. The conditions are listed in the table below.
Edit permission PA2_74
Parameter change
operation
Edit permission
response
Not assigned 0: Write enable ON Possible
OFF 0: Write enable OFF Impossible
ON 0: Write enable ON Possible
Not assigned 1: Write protect OFF Impossible
OFF 1: Write protect OFF Impossible
ON 1: Write protect OFF Impossible
Parameter setting
To assign edit permission response to a sequence output terminal, specify the corresponding
value ("29") to the output terminal function setting parameter.