CHAPTER 1 INSTALLATION
1-2
Servomotor
1
1.1 Servomotor
1.1.1 Storage Environment
Select the following environment when storing the servomotor, or when resting the machine under the
state without power distribution.
Item Environmental condition
Ambient temperature -20 to +60°C (no freezing allowed)
Ambient humidity 10 to 90% RH (no condensation allowed)
1.1.2 Operating Environment
Operate the servomotor in the following environment.
Item Environmental condition
Ambient temperature -10 to +40°C (no freezing allowed)
Ambient humidity 10 to 90% RH (no condensation allowed)
Location
Indoors at altitude 1000 m free from powder
dust, corrosive gases
and direct sunlight
Vibration
49 m/s
2
or less (3000 r/min, 0.75 kw or less)
24.5 m/s
2
or less (3000 r/min, 1 kw or more)
24.5 m/s
2
or less (1500 r/min, 2000 r/min)
Observe the following when operating.
Install indoors at a place free from rainwater and direct sunshine.
Do not operate in corrosive atmosphere including hydrogen sulfides, sulfurous acid, chlorine,
ammonia, sulfur, chlorine-based gases, acids, alkalis or salts or near flammable gases or matters.
Install at a place free from splashes of coolant, oil mist, iron powder and chips.
Install in a well ventilated environment with less vapor, oil and water content.
Install at a place advantageous for inspection and cleaning.
Install at a place with less vibration or impact.
Do not install in an airtight environment.

Table of Contents