CHAPTER 4 PARAMETER
4-44
Automatic Operation Setting Parameter
4
PA2_09 Reverse traveling unit amount for homing
No. Name Setting range
Default
value
Change
09
Reverse traveling unit
amount for homing
0 to 2000000000 [units] 0 Always
Not a compulsory item
Specify the reverse traveling amount taken in the direction opposite to the starting direction for homing
at the start of homing motion.
If a reference signal for homing (deceleration starting signal) or reference signal for shift operation is
detected during reverse travel, movement toward the homing direction after reference signal detection
begins. Use the setting to reduce the homing time.
Use if the stopping position is in the direction opposite to the starting direction for homing and the
maximum distance from the stopping position to the zero position is always known.
The unit amount depends on PA1_06 (numerator 0 of electronic gear) and PA1_07 (denominator of
electronic gear).
If neither the reference signal for homing (deceleration starting signal) nor reference signal for shift
operation is detected during reverse motion, movement in the starting direction for homing begins after
reverse motion by the preset traveling amount.
Homing speed
Homing creep speed
Speed
Time
Homing [ORG]
OFF
ON
OFF
OFF
ON ON
+
-
OFF
OFF
Reference value of reverse
traveling unit amount for
homing
+OT
-OT
Reference signal for
shift operation
Reverse traveling unit
amount for homing
Stopping position
Starting direction for homing
Home position
reference signal