CHAPTER 2 WIRING
Description of I/O Signals 2-57
2
AD0: Sequence input signal (Reference value 60)
AD1: Sequence input signal (Reference value 61)
AD2: Sequence input signal (Reference value 62)
AD3: Sequence input signal (Reference value 63)
Enter the address of positioning data to be followed, among AD0 to AD3.
Refer to the table below when entering.
<Address No. selection table>
Address
No.
AD3 AD2 AD1 AD0
Sequential
start selection
PA2_41
Operation mode In case of internal
positioning data selection: PA2_40=1
(enable)
0: Disable Address error
1: Enable Sequential start
2: Homing Homing operation
0 OFF OFF OFF OFF
3: Immediate
value data
operation
Immediate value data operation
1 OFF OFF OFF ON
Operation with positioning data 1
2 OFF OFF ON OFF
Operation with positioning data 2
3 OFF OFF ON ON
Operation with positioning data 3
4 OFF ON OFF OFF
Operation with positioning data 4
5 OFF ON OFF ON
Operation with positioning data 5
6 OFF ON ON OFF
Operation with positioning data 6
7 OFF ON ON ON
Operation with positioning data 7
8 ON OFF OFF OFF
Operation with positioning data 8
9 ON OFF OFF ON
Operation with positioning data 9
10 ON OFF ON OFF
Operation with positioning data 10
11 ON OFF ON ON
Operation with positioning data 11
12 ON ON OFF OFF
Operation with positioning data 12
13 ON ON OFF ON
Operation with positioning data 13
14 ON ON ON OFF
Operation with positioning data 14
15 ON ON ON ON
Operation with positioning data 15