CHAPTER 11 ABSOLUTE POSITION SYSTEM
Battery Installation and Replacement Procedures 11-3
11
11.2 Battery Installation and Replacement Procedures
11.2.1 Battery Installation Procedure [Frame 1]
Install the battery with the following procedure.
Appearance with the battery mounted
①
Put the battery in the battery case first.
Connect the lead wire connector of the battery to
CN5 on the front panel of the servo amplifier.
②
Fit the four tabs of the battery case into the
mounting holes on the servo amplifier front face.
Fit the tabs on A side first and then B side (or B side
first and then A side) to fit the case in readily way.
③
Check the condition if the case is fitted securely.
- Has the connector been inserted securely?
- Have all of the four battery case tabs been fitted to
the front face of the servo amplifier?
A
B