EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - PA2_40 Internal Positioning Data Selection; PA2_36 to 39 Override Settings ·······························································

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4 PARAMETER
4-76
Automatic Operation Setting Parameter
4
PA2_36 to 39 Override settings
No. Name Setting range
Default
value
Change
36 Override 1 10 Always
37 Override 2 20 Always
38 Override 4 40 Always
39 Override 8
0 to 150 [%]
80 Always
These parameters are enabled under speed and position control.
To use these signals, be sure to turn on "override enable."
With this setting, the speed can be changed during operation. For the weight of the override, refer to
the table below.
PA2_40 Internal positioning data selection
No. Name Setting range
Default
value
Change
40
Internal positioning data
selection
0: Disable 1: Enable 10 Power
Select whether the internal positioning data is enabled or disabled.
Setting “0”: Immediate value data operation over RS-485 Modbus communications
Setting “1”: Positioning data operation with address settings AD0 to AD3
Ratio of override
OFF
ON
Override
8
Override
4
Override
2
Override
1
Traveling
speed
%
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFFOFFOFF
OFFOFFOFF
OFFOFF
OFFOFF
OFFOFF
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
* For default override weight
OFFOFFON ON
OFF
ON ON

Table of Contents

Related product manuals