CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter 4-75
4
(2) Area OFF ON (If PA2_31 (point detection, area detection) is 1)
The signal is turned on if the current position is exactly or larger than the setting of the standard
parameter.
It is turned off if the position is less than the setting.
(3) Area ON OFF (If PA2_31 (point detection, area detection) is 2)
The signal is turned on if the current position is exactly or less than the setting of the standard
parameter.
It is turned off if the position exceeds the setting.
OFF ON
190.0 200.0 210.0
Current position
Area
Point detection, area detection position 1
(PA2_32)
Point detection, area detection position 2
(PA2_33)
(Standard parameter 64)
190.0 200.0 210.0
OFF ON
Current position
Area
Point detection, area detection position 1
(PA2_32)
Point detection, area detection position 2
(PA2_33)