CHAPTER 4 PARAMETER
4-88
Extended Function Setting Parameter
4
PA2_72 Station number
No. Name Setting range
Default value
Change
72 Station number Station No.: 1 to 31 1 Power
Specify the station number of the amplifier.
RS-485 type: Specify the station number of each station.
PA2_73 Communication baud rate (RS-485)
No. Name Setting range
Default value
Change
73
Communication baud rate
(RS-485)
0: 38400 [bps] 1: 19200 [bps]
2: 9600 [bps] 3: 115200 [bps]
0 Power
Specify the communication baud rate of the system combined over RS-485.
PA2_74 Parameter write protection
No. Name Setting range
Default
value
Change
74 Parameter write protection 0: Write enable 1: Write protect 0 Always
Specify parameter write protection.
Enter "1" to prohibit parameter editing. Only this parameter can be changed.
PA2_75 Positioning data write protection
No. Name Setting range
Default
value
Change
75
Positioning data write
protection
0: Write enable 1: Write protect 0 Always
Specify positioning data write protection.
Enter "1" to prohibit positioning data editing.