CHAPTER 4 PARAMETER
4-74
Automatic Operation Setting Parameter
4
PA2_31 to 34 Point detection, area settings
No. Name Setting range
Default
value
Change
31
Point detection, area
detection
0: Point detection
1: ON for positive side
2: ON for negative side
0 Always
32
Point detection, area
detection position 1
-2000000000 to 2000000000 units 0 Always
33
Point detection, area
detection position 2
-2000000000 to 2000000000 units 0 Always
34 Point detection range 0 to 2000000000 units 100 Always
Specify the output format of the "point detection, area detection" signal that is output as an output
signal (OUT signal).
In case of point detection setting, the signal is output if the servomotor is located nearly in the reference
value (point detection range)
In case of area setting, the signal is turned on or off if the servomotor position exceeds the reference
value.
(1) Point detection (If PA2_31 (point detection, area detection) is 0)
The signal is turned on if the current position is nearly the position specified in the standard
parameter.
10.0 10.0
190.0 200.0 210.0
Current position
Fixed point
OFF ON
Point detection range
(PA2_34)
Point detection, area detection position 1
(PA2_32)
Point detection, area detection position 2
(PA2_33)
(Standard parameter 64)