CHAPTER 4 PARAMETER
Input Terminal Function Setting Parameter 4-97
4
The logic of the following signals differs between those assigned to hardware CONT signals (CONT1 to
5) and those to communications CONT signals (CONT9 to 24).
In “Chapter 2 Wiring” the signal logic is described with the case assigned to hardware CONT signals
(CONT1 to 5).
Signal logic
No. Name
Hardware CONT signal:
assigned to (CONT1 to 5)
Communications CONT signal:
assigned to (CONT9 to 24)
7 +OT N.C. N.O.
8 -OT N.C. N.O.
10 Forced stop [EMG] N.C. N.O.
34
External
regenerative
resistor overheat
N.C. N.O.
N.C.: Normally closed contact
N.O.: Normally open contact
(2) Connector pin layout
The pin layout of each signal is shown in the figure below.
Assign desired functions to signals CONT1 through CONT5.
CN1
PA3_26 to 30 CONT always effective 1 to 5
No. Name Setting range
Default
value
Change
26 CONT always ON 1
27 CONT always ON 2
28 CONT always ON 3
29 CONT always ON 4
30 CONT always ON 5
Specify the number corresponding to
desired function (0 to 78)
0 Power
Specify the CONT input signal that is always enabled after the power is turned on.
The normally open contact signal is always turned on. The normally closed contact signal is always
turned off.
Functions that may not be specified with a normally open signal include alarm reset, deviation clear
and free-run.
26 M5 13 M5
25 FZ 12 *FFB
24 *FFZ 11 FFB
23 FFZ 10 *FFA
22 VREF 9 FFA
21 *CB 8 *CA
20 CB 7 CA
19 PPI 6 CONT5
18 TREF 5 CONT4
17 OUT3 4 CONT3
16 OUT2 3 CONT2
15 OUT1 2 CONT1
14 COMOUT
1 COMIN