EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - PA2_77 Initial Display of the Keypad; Display Transition at Warning Detection

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4 PARAMETER
Extended Function Setting Parameter 4-89
4
PA2_77 Initial display of the keypad
No. Name Setting range
Default
value
Change
77
Initial
display of
the keypad
(Data
displayed on
keypad)
0: Sequence mode. 1: Feedback speed. 2: Command speed.
3: Command torque. 4: Motor current. 5: Peak torque.
6: Effective torque. 7: Feedback position.
8: Command position. 9: Position deviation.
10: Command pulse frequency. 11: Feedback cumulative pulse.
12: Command cumulative pulse. 13: LS-Z pulse.
14: Load inertia ratio. 15: DC link voltage (max.).
16: DC link voltage (min.). 17: VREF input voltage.
18: TREF input voltage. 19: Input signals. 20: Output signals.
21: OL thermal value. 22: Regenerative resistor thermal value.
23: Power (W). 24: Motor temperature. 25: Overshoot unit amount.
26: Settling time. 27: Resonance frequency 1.
28: Resonance frequency 2. 40: Station number.
41: Alarm at present. 42: Alarm history . 43: Warning at present.
44: Total time - main power supply.
46: Motor running time.
0 Power
Specify the data displayed on the amplifier when the power is turned on.
PA2_78 Display transition at warning detection
No. Name Setting range
Default
value
Change
78
Display transition at
warning detection
0: No transition 1: Transition to
warning display
0 Power
Select whether or not a warning sign is displayed on the amplifier when a "cooling fan life expiration,"
"main circuit capacitor life expiration," or "low battery voltage" warning is detected.
If the replacement timing is drawing near after several years of operation, change this parameter to "1"
to show a warning on the keypad in front of the servo amplifier.

Table of Contents