CHAPTER 6 KEYPAD
6-42
Positioning Data Edit Mode
6
(5) M code
The M code output by executing positioning data can be
edited. The setting range is from 00 to FF in hexadecimal.
The minimum increment is 1.
The default value is FF.
(6) Acceleration time
Set the motor acceleration time. The setting value range is
from 0.0 to 99999.9 ms in increments of 0.1.
The setting value is the time until the motor rotation speed
reaches 2000 r/min.
(7) Deceleration time
Set the motor deceleration time. The setting value range is
from 0.0 to 99999.9 ms in increments of 0.1.
The setting value is the time until the motor rotation speed
reaches 2000 r/min.
Pd_5
FF
00
∧/∨
FF
・・・
SET
(1 sec. or over)
ESC
Pd_6
SET
(1 sec. or over)
99
----
999
.
9
Blinks three times.
Blinks three times.
----
SHIFT
ESC
ESC
Pd_7
SET
(1 sec. or over)
99
----
999
.
9
Blinks three times.
Blinks three times.
----
SHIFT
ESC
ESC

Table of Contents