CHAPTER 3 OPERATION
Operation 3-17
3
(1) After the interrupt input enable signal is turned on, the activating edge
(OFF-to-ON transition) of the first interrupt input is enabled.
(2) Allocate the interrupt input to the CN1 terminal of CONT1 to 5.
Generally, the sequence input and output signals are recognized in about
1 to 2 ms by the software, however, the interrupt input detects the signals by the
hardware. Therefore, delay in signal detection (about 0.05 ms) occurs only with
the filter circuit of CONT1 to 5.
(3) The in-position [INP] signal shown in the figure assumes the level output mode.