EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - Page 251

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 4 PARAMETER
Extended Function Setting Parameter 4-83
4
The enabled torque limit is described below.
(1) In case of position control and speed control (If PA2_57 is 0)
CONT signal * State of each limit Enabled torque limit
Torque
limit 1
Torque
limit 0
TL: TREF (analog torque limit)
CCW: Powering,
CW: Regeneration
CW: Powering,
CCW: Regeneration
OFF OFF No condition judgment
Forward rotation
torque limit
Reverse rotation
torque limit
TL Forward/Reverse rotation torque limit
Forward rotation
torque limit
Reverse rotation
torque limit
OFF ON
TL < Forward/reverse rotation torque limit TL TL
Second torque limit Forward/Reverse rotation
torque limit
Forward rotation
torque limit
Reverse rotation
torque limit
ON OFF
Second torque limit < Forward/Reverse torque
limit
Second torque
limit
Second torque
limit
TL Second torque limit
Second torque
limit
Second torque
limit
ON ON
TL < Second torque limit TL TL
Add a positive voltage to TL. The negative voltage is limited to zero.
A negative setting is limited to zero.
If PA2_57 is 1, the torque limit is always the TL value.
(2) In case of torque control
The forward rotation torque limit and reverse rotation torque limit are followed.
(3) Torque limit for controlled stop action (under position or speed control) (If PA2_57 is 0)
CONT signal * State of each limit Enabled torque limit
Torque
limit 1
Torque
limit 0
TL: TREF (analog torque limit)
CW deceleration
stop
CCW deceleration
stop
Forward rotation torque limit Third
torque limit
Third torque limit Third torque limit
OFF OFF
Forward/Reverse rotation torque limit <
Third torque limit
Forward rotation torque
limit
Reverse rotation torque
limit
TL, forward/reverse torque limit Third
torque limit
Third torque limit Third torque limit
OFF ON
TL, forward/reverse torque limit < Third
torque limit
TL or forward rotation
torque limit, whichever
is less
TL or reverse rotation
torque limit, whichever
is less
Second torque limit, forward/reverse
rotation torque limit Third torque limit
Third torque limit Third torque limit
ON OFF
Second torque limit, forward/reverse
rotation torque limit < Third torque limit
Second torque limit or
forward rotation torque,
whichever is less
Second torque limit or
reverse rotation torque,
whichever is less
TL, second torque limit Third torque
limit
Third torque limit Third torque limit
ON ON
TL, second torque limit < Third torque
limit
TL or second torque
limit, whichever is less
TL or second torque
limit, whichever is less
If PA2_57 is 1, the torque limit is always the TL value.

Table of Contents