CHAPTER 6 KEYPAD
Positioning Data Edit Mode 6-39
6
6.8 Positioning Data Edit Mode
In the positioning edit mode, you can edit positioning status, target position, rotation speed, stand still
timer, M code, and acceleration and deceleration time.
Procedure (common)
(1) Positioning status
Set data relevant to the positioning data.
Pd_1
Pd_2
Pd_3
Pd_4
Pd_5
Pd_6
Pd_7
Pd_1
A
.
00
.
0
SET
(1 sec. or over)
ESC
i
INC
Indication
Command
method
A
ABS
4th digit
co
Continuous
Indication
Step mode
00
No
designation
2nd and 3rd digits
cE
Cycle end
1
Output at startup
Indication
M code setting
0
Disable
1st digit
2
Output at
completion
Pd_1
Po01
no
.
01
n
o
.
02
∧/∨
n
o
.
15
・・・
SET
(1 sec. or over)
ESC
SET
(1 sec. or over)
ESC
∧/∨
P
d
_7
・・・
P
d_2
: Positioning status
: Target position
: Rotation speed
: Stand still timer
: M code
: Acceleration time
: Deceleration time