CHAPTER 14 PC LOADER
14-20
Detail Description of Function
14
Tracing procedure
[1] Select the desired waveform.
[2] Select the sampling time.
[3] Press the "START/STOP" button to start to trace.
[4] Press the "START/STOP" button to stop tracing.
Waveform that can be acquired
Up to eight channels* of analog or digital signals can be acquired.
Waveforms that can be acquired are shown below. (All digital I/O signals can be traced.)
* Up to four analog signals can be acquired. If four analog signals are selected, no more digital
signals are acquired.