Operation Manual – Mirroring
Quidway S3900 Series Ethernet Switches Chapter 1 Mirroring Configuration
Huawei Technologies Proprietary
1-8
Operation Command Description
Enter Ethernet port
view of the destination
port
interface interface-type
interface-number
Define the current port
as the destination port
mirroring-group group-id
monitor-port
Required
LACP and TCP must be
disabled on the destination
port
Exit current view
quit
Enter Ethernet port
view of the source port
interface interface-type
interface-number
Configure the source
port and specify the
direction of the
packets to be mirrored
mirroring-group group-id
mirroring-port { both |
inbound | outbound }
Required
Display parameter
settings of the
mirroring
display mirroring-group
{ all | local }
Required
This command can be
executed in any view.
III. Configuring port mirroring in system view
Table 1-8 Configure port mirroring in system view
Operation Command Description
Enter system view
system-view
Create a port mirroring
group
mirroring-group group-id
local
Required
Configure the
destination port
mirroring-group group-id
monitor-port monitor-port
Required
LACP and TCP must be
disabled on the
destination port.
Configure the source
port and specify the
direction of the
packets to be mirrored
mirroring-group group-id
mirroring-port
mirroring-port-list { both |
inbound | outbound }
Required
Display parameter
settings of the
mirroring
display mirroring-group { all |
local }
Optional
This command can be
executed in any view.